vestibular balance testing equipment, videonystagmography diagnostic testing, new VNG for sale, used VNG for sale

Fall and Balance Prevention Programs for patients with balance disorders

Home...... VNG Equipment ...... E-Z VNG ...... Caloric Irrigators ...... Video Frenzel ...... Billing/Coding

Financing ...... FAQs ...... Training ...... Group Training ...... Marketing......About......Contact Us

 




YouTube VNG Videos



E-Z and Full Feature Premium VNG Devices


Caloric Irrigators

Video Frenzel Goggles


Balance Assessment Platforms


TBI-Concusssion Management



Pre-owned/Demos


VNG Difra Comparison Chart



YouTube VNG Videos



Secure Health's Better Balance™ technology offers a series of cutting edge diagnostic equipment, including VNG videonystagmography testing equipment, designed for an accurate diagnosis. We also provide proven treatment programs and an effective patient education program.


Sample VNG Software Report: Disoft II

VNG expo live demo videonystagmography

Treatment Solutions:

Proven Better Balance™ technology

Testing to identify neurogenic deficiency

Origin testing for vestibular disorder isolation

Position techniques to induce patient dizziness

Caloric tests
Tracking tests

Video captured and quantified Nystagmus testing (VNG)

Please contact us for more information:

Call 260-436-1436

Balance disorders interfere with an individual’s daily activities, including their ability to work or travel, and may result in a higher risk of falling. Balance disorders can be caused by a number of underlying issues, including neurological, vestibular or proprioceptive.

Secure Health, Inc. offers a series of cutting edge diagnostic tests and equipment, inlcuding VNG videonystagmography testing equipment, designed for an accurate diagnosis. We also provide effective treatment programs and patient education.

 

Keywords:
VNG equipment, balance assessments, treat balance disorders, better balance, falls and fall prevention, VRT exercises, balance testing, neurovestibular sciences, VNG, videonystagmography, ENG, vestibular disorders, vestibular, electronystagmography, diagnostic testing, dizziness, prevent falls, vertigo, disequilibrium, caloric testing, BPPV, TBI, concussions, concussions, vestibular concussions, Meniere's disease, vestibular balance rehab, vng balance evaluation, vestibular balance function testing, ENT, audiology, audiologist, neurotologist, neuro tologist, CME, Continuing Medical Education credits

 

 

NEW! Now introducing the basic E-Z VNG

with premium touchscreen software
and the most current Windows 10 compatibility
[more]


Competitive VNG options for most budgets



Difra Headstar VNG System


Purchase Premium VNG Diagnostic Equipment

New Vestibular Balance Testing Equipment


Difra Full Feature VNG

HeadStar – Monocular VNG System NysStar VNG Equipment
2 Channel, 1 Camera

• Test spontaneous nystagmus, positional and positioning nystagmus, plus gaze nystagmus, random saccades, optokinetics (OPK), plus gaze nystagmus, active head rotation and calorics

• Video recording and replay of tracking of the eye

• High definition camera easily moves from left to right

• Eye automatic centering

• Removable eye cover for vision defined recording

• Automatic comprehensive, customizable reports with age-dependent normative data

• Goggle is designed with a bridge hinge to fit a broader range of head shapes/sizes

• Export results over network (intranet or internet) to electronic medical records. All data is stored on the disk and can be archived automatically.

• Multiple levels of password security for doctor, staff and HIPAA compliance -- only available with full-featured version

• Reduce downtime--our technical support team can easily remote access your VNG software to troubleshoot and resolve software or hardware issues

• Billable under codes: 92540, 92543 (4 units) and 92546. Refer to our billing and coding page for optional codes.

• Manufactured by Difra Instrumentation -- Difra is a leading global manufacturer of diagnostic balance technology for more than 48 years.

 

Difra full feature VNG testing capabilities include:

Calibration; Random Saccades; OPK Optokinetics - Horizontal/Vertical; AHR Active Head Rotation - Horizontal/Vertical; Spontaneous Nystagmus, Gaze - Up, Down, Right, Left; Dix-Hallpike - Left/Right; Body Positioning - Supine, Left, Right; Head - Left/Right; Calorics - Warm Right, Warm Left, Cool Right, Cool Left


DIFRA BASIC E-Z VNG PRODUCT INFORMATION



Difra Full Feature VNG:

NysStar II – Binocular VNG System
4 Channel, 2 Cameras

Best choice for concussion - TBI management

• Test spontaneous nystagmus, positional and positioning nystagmus, random saccades, optokinetics (OPK) plus gaze nystagmus, active head rotation and NysStar II VNG Device calorics

• Video recording and replay of tracking of the eye

• Video goggles with two USB 2.0 digital cameras – resolution of 640x480 pixels

• Open-field goggle assembly

• Removable eye cover

• External adjustments for focus and X-Y centering

• Wireless remote control (foot switch remote control available)

• Automatic comprehensive, customizable reports with age-dependent normative data

• Export results over network (intranet or internet) to electronic medical records. All data is stored on the disk and can be archived automatically.

• Multiple levels of password security for doctor, staff and HIPAA compliance -- only available with full featured version

• Reduce downtime--our technical support team can easily remote access your VNG software to troubleshoot and resolve software or hardware issues

• Billable under codes: 92540, 92543 (4 units) and 92546. Refer to our billing and coding page for optional codes.NysStar II

• Manufactured by Difra Instrumentation -- Difra is a leading global manufacturer of diagnostic balance technology for more than 48 years.

 

Difra full feature VNG testing capabilities include:

Calibration; Random Saccades; OPK Optokinetics - Horizontal/Vertical; AHR Active Head Rotation - Horizontal/Vertical; Spontaneous Nystagmus, Gaze - Up, Down, Right, Left; Dix-Hallpike - Left/Right; Body Positioning - Supine, Left, Right; Head - Left/Right; Calorics - Warm Right, Warm Left, Cool Right, Cool Left

 

DIFRA BASIC E-Z VNG PRODUCT INFORMATION

Overview of Full Features for
Difra HeadStar & NysStar II VNG Systems


--Active head rotation/AHR

--Wireless remote control

--Visiobox oculography module

--200 Hz tracking upgrade available for NysStar II

--Laptop computer - 15.6"

--32" Monitor - Standard

--Camera resolution: 640 X 480 pixels

--Most current = Windows 10 compatible

--EMR integration

--User intuitive software

--Video recording/replay capabilities

--Analyze, edit and modify tests

--Automatic results analysis

--Sound indication for test progress

--Unlimited test sequence protocols

--Includes database - Firebird or MySQL with PDF export

--Customizable reports

--Multiple levels of password security for doctor, staff and HIPAA compliance

--Camera moves easily to either eye

--Eye cover for vision denied recording

--Remote access technical support reduces downtime

 


Difra Full Featured VNG Equipment List

HeadStar and NysStar VNG System Components:

1. VNG (videonystagmography) interface

2. VNG (videonystagmography) goggles

3. High definition USB camera

4. 50 Hz Tracking Speed (200 Hz upgrade available for NysStar II)

5. 32" monitor for effective patient stimulus -- projector or larger monitor available

6. Caloric irrigator: AIR (standard);

7. Laptop computer - 15.6"

8. VNG software

9. Connecting cables

10. Durable carrying case for VNG goggles, interface and components

Optional upgrades for caloric choices: Water-cooled air or water

Secure Health, Inc. is the exclusive US agent for Difra Instrumentation, a world's leading manufacturer of diagnostic balance disorder technology for more than 48 years.
November, 2017

Which is best for my application, VNG Monocular (one camera, 2 channel) or VNG Binocular (two cameras, 4 channel)?

The primary advantage to binocular recording rather than monocular is that with monocular you can often overlook disconjugate eye movements (i.e., when the eyes are not moving synchronously together).

This would be most common with paralyses of one or more of the extraocular eye muscles or with lesions affecting the medial longitudinal fasiculus which is the major pathway that pairs the eyes together for versional horizontal deviations. Often times you may also have one eye that captures or records poorer than the other such as with individuals who have had prior eye surgeries in which case having dual recording is also more beneficial.

--Troy D. Hale, Au.D, FAAA

--Doctor of Audiology, Asst. Professor ATSU



 

DISCLAIMER:

Information presented on this web site may have changed since being published. Secure Health, Inc. may change pricing, terms and conditions at any time without prior written notice. Please refer to your specific quote and/or invoice/lease contract and/or bill of sale for details.

Secure Health, Inc. is the exclusive US agent for Difra Instrumentation, a world's leading manufacturer of diagnostic balance disorder technology for more than 48 years.

 

 

VISIT OUR NEW WEB SITE:

vngequipment.com

 
     

Copyright © 2018 Premium Better Balance™ Diagnostic Equipment and Technology, exclusively from Secure Health, Inc. All rights reserved.